Professional body composition analyser and diagnostic equipment

The diagnostic equipment of a recovery centre measures and tracks: body composition by multi-frequency bioimpedance (BIA), aerobic capacity by cardiopulmonary exercise testing (VO2max), heart rate variability (HRV). It is used to monitor progress and personalise programmes, not for a medical diagnosis. The choice comes down to the measurement method, repeatability, the tracking software and data export.

W 500H 1 200D 600GABARIT TYPE · mm · DIAGNOSTICS

A diagnostics offer turns an equipment centre into a monitoring centre: measurements on arrival, comparison over time, reports handed to the client. Three families come from the factory or from specialist distributors: BIA analysers, VO2max systems, HRV sensors. This page compares the formats, the requirements (quiet room, calibration, GDPR protection) and the documentation. The measurements are monitoring and wellbeing data, with no medical interpretation. Indicative budgets excl. VAT, excluding transport.

Machine types

3 types
TypeTechnologyCapacityPowerFloor areaIndicative budget
Body composition analyser (BIA)Segmental multi-frequency bioimpedance, platform + handles, printer or export1 person, measurement in 1 to 2 min0.1 kW, 230 V2 m²specified in the quote
VO2max system (cardiopulmonary testing)Gas analyser + mask, ergometer (bike or treadmill), test software1 person, test of 15 to 30 min0.5 to 2 kW (ergometer)6 to 10 m²specified in the quote
HRV measurementStrap or sensor, app or software, measurement session of 3 to 5 min1 personBatteryNone (reception desk)specified in the quote

Indicative budget excluding transport, installation and local taxes. Bespoke quote.

How to choose

Start with the BIA analyser: it is the simplest, quickest and most useful diagnostic equipment for monitoring. VO2max and HRV come next if your clientele is sporty.

Premises prerequisites

Electricity230 V 16 A; dedicated line for a cardiopulmonary testing treadmill.
RoomQuiet room, stable temperature; level floor for the BIA platform.
DataMeasurements are personal data: plan for information, consent, retention period and security (GDPR).
SupervisionTrained operator; VO2max test under supervision according to the manufacturer's instructions.

Available customisation

Casing and welcome screen in your branding
Measurement reports with your logo (depending on the software)

Documentation supplied

  • EU declaration of conformity (low voltage, EMC, RoHS; radio for the sensors)
  • Measurement repeatability and calibration sheet
  • Manual in French and calibration procedure
  • Labelling

Generic list by family: the exact content depends on the model and its file. We check and complete the compliance documentation of every machine before shipment.

Running costs

EnergyLow, except for the ergometer.
ConsumablesMasks or filters (VO2max), wipes, printer paper, calibration gas depending on the model.
MaintenancePeriodic calibration, software updates.

Example sheets

2 sheets

Two typical configurations per family, with typical specifications to be replaced by those of the selected model.

Visual to be suppliedModelPowerCapacity
Image to be supplied: Multi-frequency body composition analyserMulti-frequency body composition analyserPlatform with handles, segmental multi-frequency bioimpedance, printed or exported report: a centre's entry measurement.0.1 kW1 person, 1 to 2 min
Image to be supplied: VO2max system (cardiopulmonary testing)VO2max system (cardiopulmonary testing)Gas analyser with mask, ergometer and test software: aerobic capacity measurement for a sporty clientele.0.5 to 2 kW1 person, test of 15 to 30 min

Frequently asked questions

What does a BIA analyser measure?

The impedance of tissues at several frequencies, converted by the software into estimates of lean mass, fat mass and water, by segment. Repeatability (same person, same conditions) is the quality criterion.

Are these measurements medical?

No: they are monitoring and wellbeing data, with no medical interpretation. All communication must stay within that framework.

Is a professional needed for a VO2max test?

The test is carried out under the supervision of a trained operator, following the manufacturer's instructions and your country's rules for exercise testing.

How should the data be managed?

Informing the client, consent, retention period, software security: measurements are personal data within the meaning of the GDPR.

What budget should I plan for?

Indicative ranges appear in the table as soon as they are supplied; excluding transport and local taxes. Quote tailored to your project.

Further reading

  • Body composition analyser: which one for a centre? coming soon
  • Adding a diagnostics offer: VO2max, HRV, body composition coming soon
  • The 12 essential pieces of equipment for a biohacking centre coming soon

Related solutions : Sports clubs · Gyms · Entrepreneurs

Let us price your Diagnostics

Tell us which families interest you: we come back with a comparison of factories and a first estimate.

KRV · 03.11/12

Budget, choice of machines, premises, import compliance, reading a forecast: the free guide “Opening a centre” and its two templates to fill in.

Get the guide