- Sheet
- KRV-CAT-BAINS-
- Family
- Cold plunge baths
- Types
- 3
- Status
- To be quoted
- Rev.
- A
Professional cold plunge bath
A professional cold plunge bath differs from a domestic tub in three ways: a chiller sized to hold 3 to 6 °C with back-to-back sessions, continuous filtration and disinfection suited to use by the public, and a washable stainless steel or composite tank. The factory price depends on cooling capacity, volume and finishes.
The cold plunge bath is often the least expensive item in a recovery centre, and an undersized bath shows quickly: water climbing back above 10 °C after three sessions, insufficient filtration, a tank that is hard to clean. This page describes the factory configurations (single bath, double bath, contrast circuit with hot bath), the cooling capacity to plan for according to footfall, and the hygiene requirements for water open to the public. Indicative budgets excl. VAT, excluding transport and installation.
Machine types
3 types| Type | Technology | Capacity | Power | Floor area | Indicative budget |
|---|---|---|---|---|---|
| Single regulated cold plunge bath | Stainless steel or composite tank 300 to 500 L, 1 to 2 HP chiller, filtration + disinfection (UV, ozone or chlorine) | 1 person | 1 to 2.5 kW, 230 V | 3 to 4 m² + technical access | specified in the quote |
| Double or multi-person bath | Tank 800 to 1,500 L, 2 to 4 HP chiller, reinforced filtration | 2 to 4 people | 2.5 to 5 kW, 230 V or 400 V | 6 to 10 m² | specified in the quote |
| Contrast circuit | Cold bath 3 to 6 °C + hot bath 38 to 40 °C, separate units, filtration per basin | 2 to 6 people | 4 to 9 kW | 10 to 20 m² in a wet area | specified in the quote |
Indicative budget excluding transport, installation and local taxes. Bespoke quote.
How to choose
A cold plunge bath is sized on your schedule, not on the catalogue: number of users per hour, room temperature, and how long the chiller needs to recover between two sessions. We ask the factory for the temperature recovery curve before approving a model.
Premises prerequisites
| Electricity | 230 V 16 A per single bath; 400 V for a contrast circuit. 30 mA residual-current protection in a wet area. |
|---|---|
| Wet area | Non-slip floor with drain, waterproofing, shower nearby, room ventilation against condensation. |
| Water supply and drainage | Filling and draining close by; water renewal according to the hygiene plan. |
| Floor load | 500 L of water = 500 kg plus the tank: check the floor structure, especially on an upper floor. |
Available customisation
Documentation supplied
- EU declaration of conformity (low voltage, EMC, RoHS; refrigerant declared)
- Manual in French: filling, adjustment, filtration, disinfection, winterising
- Standard hygiene plan: water renewal frequency, disinfectant checks, tank cleaning
- Labelling: power, refrigerant and charge, ingress protection rating
Generic list by family: the exact content depends on the model and its file. We check and complete the compliance documentation of every machine before shipment.
Running costs
| Energy | Continuous cooling; consumption depends on tank insulation and footfall. |
|---|---|
| Consumables | Water, disinfectant or UV lamp, filter cartridges. |
| Maintenance | Tank and filter cleaning according to the hygiene plan, annual check of the chiller. |
Example sheets
2 sheetsTwo typical configurations per family, with typical specifications to be replaced by those of the selected model.
| Visual to be supplied | Model | Power | Capacity |
|---|---|---|---|
| Single-person regulated stainless steel cold plunge bath304 stainless steel tank with chiller, filtration and UV disinfection, 3 to 6 °C: the reference bath for professional use. | 1.5 to 2.5 kW | 1 person | |
| Two-person hot / cold contrast circuitCold bath at 3 to 6 °C and hot bath at 38 to 40 °C side by side, separate units, filtration per basin: the contrast area of a full centre. | 6 to 9 kW | 2 + 2 people |
Frequently asked questions
What temperature and what cooling capacity?
Most centres aim for 3 to 6 °C. Capacity is calculated from the number of back-to-back sessions and the room temperature: a 1 HP chiller will not hold 5 °C with ten users per hour. We size it from your schedule.
How is water hygiene ensured?
Continuous filtration, disinfection (UV, ozone or chlorine depending on the model), a shower before immersion and a planned water renewal. The local obligations for water open to the public must be checked with the competent authority in your country.
Stainless steel or composite?
304 or 316 stainless steel is the most durable and the easiest to disinfect; composite is lighter and cheaper. The choice depends on budget and the look you want.
Can a cold plunge bath be installed on an upper floor?
Yes, if the structure supports the load (full tank plus users) and the wet area is properly waterproofed. A check by a structural engineering firm is recommended.
What budget should I plan for?
Indicative ranges by configuration appear in the table above as soon as they are supplied; excluding transport, installation and local taxes. Quote tailored to your project.
Further reading
- Professional cold plunge: technologies, hygiene and price
- Water hygiene for a cold plunge open to the public coming soon
- Designing a sauna and cold plunge contrast circuit coming soon
Related solutions : Gyms · Sports clubs · Physiotherapists
Let us price your Cold plunge baths