Professional hyperbaric chamber: price, types and pressures
The price of a professional hyperbaric chamber depends on four choices: the structure (soft or rigid), the working pressure (1.3 to 2.0 ATA for wellbeing models), the position (seated or lying) and the supply of air or concentrated oxygen. Transport, installation, customisation and maintenance come on top. Our ranges are indicative and exclude VAT: the firm figure appears on a quote drawn up for your premises and your configuration.
By Kryvana · published 27 November 2026 · updated 27 November 2026
What drives the price of a hyperbaric chamber
A hyperbaric chamber is not bought like a machine you plug into a socket. It is an enclosure in which a person sits while the air pressure rises, stabilises, then comes back down. Everything that holds, produces, measures and releases that pressure has a cost, and that cost varies widely from one family of chambers to another.
Before comparing two offers, always separate five items. A factory or a European distributor that quotes a single figure does not say which of these items it covers.
| Item | What it covers | What makes it vary |
|---|---|---|
| The machine | Enclosure, door or closure, valves, control panel, compressor | Soft or rigid structure, working pressure, number of places |
| Equipment and options | Air conditioning (built in on seated rigid models), oxygen concentrator (optional on rigid models), intercom, viewing ports | Family, model, level of comfort targeted |
| Customisation | Shell or cover colour, logo, rating plate in your branding | Number of items branded, factory requirements |
| Transport and installation | Freight, handling, positioning, commissioning, training | Weight (60 kg to 800 kg depending on the family), access to the premises |
| Operation | Energy, filters, seals, periodic checks | Number of sessions per day, intervals set by the manual |
Indicative ranges by family
We do not publish prices until they are backed by real models and verified factory quotes. The ranges below will be filled in at that point.
| Family | Working pressure | Capacity | Indicative range excl. VAT |
|---|---|---|---|
| Soft chamber, lying | 1.3 to 1.5 ATA | 1 person lying down | On request |
| Rigid chamber, seated | 1.5 to 2.0 ATA | 1 to 2 people seated | On request |
| Rigid chamber, lying | 1.5 to 2.0 ATA | 1 person lying down | On request |
Indicative budget excluding transport, installation and local taxes. Tailored quote.
Three items complete this table and have to be priced case by case:
- the extra cost of an optional oxygen concentrator on a rigid chamber: on request;
- transport, handling and installation: on request;
- the lead time between order and commissioning: on request.
Why two chambers that look identical do not cost the same
In a photo, two steel shells with viewing ports look alike. The price gap lies in what you cannot see: the design of the structure and the door, the valves, the air conditioning, the compressor, and above all the file that proves the structure has been calculated and tested. A chamber sold without a pressure test report can cost less simply because part of the work has not been done, or has not been documented.
Types of chamber: soft or rigid, seated or lying
Soft or rigid is the first choice, and the one that weighs most on the overall budget. It also commits you on premises, delivery and maintenance.
| Criterion | Soft chamber, lying | Rigid chamber (seated or lying) |
|---|---|---|
| Structure | Reinforced textile envelope, double airtight zip closure | Steel or composite shell, door, viewing ports |
| Working pressure | 1.3 to 1.5 ATA | 1.5 to 2.0 ATA |
| Compressor | External, can be moved to an adjoining room | Depends on the model; air conditioning built in on seated models |
| Weight | 60 to 100 kg (example sheet) | 300 to 800 kg |
| Concentrated oxygen | Not provided on the example sheet, to be clarified | Concentrator optional |
| Wear parts | Textile envelope and zips | Door seals; valves to be checked |
| Budget | The lowest of the range | Higher, for the machine and for preparing the premises |
The soft chamber is the entry-level option: cheaper, lighter, limited to 1.3 to 1.5 ATA and to the lying position, with an envelope and zips to be replaced according to the maintenance logbook. It suits testing demand before committing a heavier budget.
The rigid chamber goes up to 2.0 ATA. It offers more comfort (viewing ports, air conditioning, a seated position is possible) and a longer service life, for a higher budget and weight. It belongs in a centre designed around it, such as our Complete Centre pack, where the chamber takes its place in the cabin area.
The detailed comparison, with the day-to-day operating questions, is the subject of a separate article: soft or rigid hyperbaric chamber: which one for a centre coming soon.
Seated or lying, one or two places
The second choice concerns the position and the capacity.
Lying, one place. This is the configuration of the soft chamber and of some rigid ones. The rigid lying chamber is the bulkiest format in the range: allow 8 to 12 m² including circulation space. See the example sheet for the soft lying chamber, 1.3 ATA.
Seated, one to two places. The shell is taller than it is long. The client sits down and communicates with the operator through an intercom and the viewing ports. It is the most comfortable format for a centre, and the one we offer to spas and hotels. Our example sheet for the rigid seated chamber, 1.5 ATA gives typical dimensions of 1,500 mm high, 900 mm wide and 1,400 mm deep, for 350 to 500 kg.
A session lasts 60 to 90 minutes, to which compression and decompression are added, 5 to 10 minutes each on the example sheet for the rigid seated chamber. A single-place chamber therefore welcomes few clients per day: it is low-turnover equipment, and its revenue depends on the occupancy rate and on your pricing policy. The rigid seated family exists in one or two places: a two-place model receives two clients per session, provided your clientele accepts sharing the enclosure. Its floor area and price have to be clarified model by model.
To test these assumptions with your own figures, use the profitability simulator. Indicative simulation based on your assumptions. It is neither a promise of results nor financial advice.
What the stated pressures mean
ATA: an absolute pressure
Chamber sheets express the working pressure in ATA. This unit designates an absolute pressure, that is, counted with ambient air pressure included: in the open air, you are already at about 1 ATA. Taking one atmosphere as the normal atmospheric pressure of 1,013 mbar retained by Directive 2014/68/EU, 1.3 ATA corresponds to about 0.3 bar above ambient pressure, 1.5 ATA to about 0.5 bar and 2.0 ATA to about 1 bar. Have the manufacturer confirm in writing, for the selected model, that the working pressure given on the data sheet is indeed an absolute pressure.
The models offered to wellbeing centres operate between 1.3 and 2.0 ATA. We make no claim about the effects of any particular pressure: the choice depends on the model and on the protocols the operator defines.
Bar gauge: the pressure used in European texts
The Pressure Equipment Directive 2014/68/EU does not speak in ATA. Its Article 2 defines pressure as "pressure relative to atmospheric pressure, i.e. gauge pressure". In other words, on a gauge ambient air is worth zero, whereas in ATA it is worth about one. The same text takes a normal atmospheric pressure of 1,013 mbar as its reference (Article 4).
A figure in ATA and a figure in bar therefore cannot be compared directly. When a factory writes "1.5" with no unit, or mixes ATA, bar and kPa in the same document, ask for the gauge pressure, in bar, in writing.
Working pressure, maximum allowable pressure, test pressure
Three different pressures circulate in a serious file. Mixing them up distorts any comparison.
- The working pressure is the one at which the chamber operates during the session. It is the figure on commercial sheets (1.3 to 2.0 ATA).
- The maximum allowable pressure, noted PS, is defined by the Directive as the maximum pressure for which the equipment is designed, as specified by the manufacturer. It can be higher than the working pressure. It is this, not the working pressure, that decides the scope of the Directive and the classification of the equipment.
- The test pressure, noted PT, is the one applied during the strength test. For pressure vessels, Annex I of the Directive generally sets a hydrostatic test at a pressure at least equal to the higher of two values, one of which is the maximum allowable pressure multiplied by 1.43.
A sheet that gives only the working pressure tells you nothing about the design margin. Ask for the three values, the valve opening pressure and the date of the test. Reading the sheet line by line is detailed in reading a chamber's data sheet: pressure, air, oxygen, flow coming soon.
Air or oxygen: supplying the chamber
A chamber needs a continuous supply of air to rise in pressure, hold it and renew the atmosphere of the enclosure. This supply relies on one or two devices, whose sizing affects price, noise and maintenance.
The compressor
On a soft chamber, the compressor is external and can be moved to an adjoining room to reduce noise in the cabin. It runs throughout the session, as does the air conditioning when the chamber has it. A UPS is recommended: a power cut must not catch the operator off guard while a client is inside the enclosure.
Questions to put to the factory: air flow, noise level, filtration, maximum length of the hose if the compressor is remote, how the chamber behaves if the compressor stops. The values themselves depend on the model: on request.
The oxygen concentrator
The concentrator is an option on rigid chambers. It changes the budget, but above all the safety rules: distances from heat sources, ban on flammable materials, ventilation of the room. These rules are detailed in the manual and must be displayed.
Before choosing this option, have three points clarified in writing: how the oxygen is distributed in the enclosure, the concentration reached in the chamber's atmosphere, and how the manufacturer has taken this supply into account in its risk analysis. Directive 2014/68/EU sorts fluids into two groups to determine the category of an item of equipment, and places "oxidising gases, category 1" in group 1 (Article 13). Whether the oxygen supply changes the classification of a given model is a question for the manufacturer and for a consultant, not a matter of commercial judgement.
Premises requirements: what comes on top of the machine price
Here is what we check against the plans before any firm quote.
| Item | Soft chamber | Rigid chamber |
|---|---|---|
| Electricity | Dedicated line, 230 V 16 A | Dedicated line, 230 V, or 400 V for an air-conditioned rigid chamber |
| Power | 1 to 2 kW | 2 to 4 kW |
| Floor area | 5 to 7 m², floor mat | 6 to 10 m² (seated), 8 to 12 m² (lying) |
| Floor and load | Level floor | Level floor bearing 300 to 800 kg |
| Delivery access | Parcel of 60 to 100 kg | To be checked according to the diameter of the shell |
| Ventilation | Ventilated room | Room air renewal; with a concentrator, rules in the manual |
| Safety | Operator present, decompression procedure displayed | Circulation space, visual contact with the operator, procedure displayed |
Four points are expensive when discovered too late.
- Access. Doors, corridors, lift, stairs: for a rigid chamber, the diameter of the shell decides feasibility. Have the factory state the form in which the shell is delivered. We ask for the dimensions of the delivery route before selecting a model.
- Floor loading. 300 to 800 kg on a few support points, on an upper floor, has to be validated with the landlord or an engineering firm.
- The 400 V supply. If the premises do not have one, creating it adds to the budget and to the schedule.
- The presence of an operator. A chamber does not run on a self-service basis. A trained person stays present during the session, sees the client and knows the decompression procedure. This staff time is part of the real cost of the session.
The Pressure Equipment Directive 2014/68/EU
The first European text to examine is Directive 2014/68/EU, which we reread for this article. It concerns the product and its placing on the market, not the operation of your centre.
What the text covers, and its limits
Article 1 sets the scope: the Directive applies to the design, manufacture and conformity assessment of pressure equipment and assemblies with a maximum allowable pressure PS greater than 0.5 bar. This pressure is counted as gauge pressure, as seen above.
The same article lists exclusions. Two of them are worth knowing for a chamber buyer:
- point (f): equipment classified at most in category I and covered by certain other directives, among them the Machinery Directive and the Low Voltage Directive;
- point (o): "pressure equipment consisting of a flexible casing", for which the text gives as examples tyres, air cushions, inflatable craft "and other similar pressure equipment".
Set these elements against the stated pressures. A 1.3 ATA soft chamber operates at about 0.3 bar gauge, below the 0.5 bar threshold; but the threshold applies to the maximum allowable pressure set by the manufacturer, not to the working pressure, and the text does not say whether a soft chamber is among the "similar" equipment of point (o). A low-pressure soft chamber can therefore fall outside the scope of the Directive; a rigid chamber at 1.5 or 2.0 ATA falls in principle under the Directive, subject to its exclusions. We do not settle this point for a given model. The manufacturer must state in writing under which texts it declares its model and why; its answer is to be validated by a regulatory consultant. Outside the scope of this Directive, a chamber does not escape the other texts cited below.
Thresholds, categories and the involvement of a body
For vessels intended for gases, Article 4 subjects to the essential safety requirements of Annex I those that exceed certain limits. For group 2 fluids, these limits are a volume above 1 litre with a PS·V product (maximum allowable pressure multiplied by volume) above 50 bar·L, or a PS above 1,000 bar.
Below these limits, paragraph 3 of the same article provides that the equipment is designed and manufactured in accordance with sound engineering practice, that it is accompanied by adequate instructions for use and that it does not bear the CE marking under this Directive. This last point deserves attention: a CE marking may be due under another text (low voltage, electromagnetic compatibility) without the pressure part being covered. Hence the value of reading which texts the declaration cites.
Above these limits, Article 13 and Annex II classify the equipment in categories I to IV, in increasing order of hazard, based on its pressure, its volume and the fluid group. The category determines the conformity assessment procedure (Article 14 and Annex III): category I falls under module A, internal production control by the manufacturer; the modules provided for categories II to IV involve a notified body. The manufacturer chooses among the procedures provided for its category, or for a higher category.
For the buyer, this comes down to three simple questions: which PS, which volume, which category? Then a fourth: which module was applied, and by which body where relevant?
What the Directive requires of the importer
Article 8 speaks directly to our role. Before placing on the market equipment subject to the requirements of Annex I, the importer ensures that the manufacturer has carried out the appropriate conformity assessment procedure, has drawn up the technical documentation, that the equipment bears the CE marking and that it is accompanied by the instructions and safety information. These instructions must be written in a language easily understood by users, as determined by the Member State concerned. The importer also indicates its name and postal address on the equipment.
This is the meaning of our commitment, stated without embellishment: we check and complete the compliance documentation of every piece of equipment before shipment. The detail of the procedure is on the Compliance page, and the article-by-article analysis of the text is in pressure equipment: what a chamber must comply with coming soon.
Directive 2014/68/EU is not the only text to examine. A chamber includes a compressor, a control panel, sometimes air conditioning: the Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility Directive 2014/30/EU, the RoHS Directive 2011/65/EU and Regulation (EU) 2023/988 (General Product Safety Regulation) also come into the analysis, without our stating here that a specific model complies with them.
The documentation to demand before paying
A low price without a file is not a good deal: it is a risk you buy along with the machine. Here are the documents we ask the factory for before selecting it, and that you must find in the binder handed over at delivery.
- The EU declaration of conformity, signed, dated, with the name and position of the signatory, the exact model reference and the list of the texts and standards under which the manufacturer declares the model, for the pressure structure as well as for the electrical equipment. Under Directive 2014/68/EU, its model (Annex IV) also states the conformity assessment procedure applied and, where relevant, the notified body and the number of its certificate.
- The technical file: strength calculations, pressure test reports, diagrams.
- The manual for operation, compression and decompression, and maintenance, in French. The Directive requires it to cover assembly, commissioning, use and maintenance, including checks by the user.
- The labelling and the rating plate: maximum allowable pressure, volume, pictograms. Annex I of the Directive provides in particular for the year of manufacture, the identification of the equipment and its permissible limits, as well as, depending on the type of equipment, the volume in litres, the test pressure and its date, and the set pressure of the safety device.
- The maintenance logbook and the inspection intervals.
The warning signs that should stop you
- A "CE certificate" issued by a laboratory and presented as sufficient: the EU declaration of conformity is drawn up under the sole responsibility of the manufacturer; when a notified body is involved, it cites its name, its number and the certificate issued.
- A generic document covering the whole range, with no model reference.
- Standards cited without an edition number, or texts repealed years ago. Directive 2014/68/EU replaced Directive 97/23/EC, repealed with effect from 19 July 2016: a recent declaration that cites only the old one raises questions.
- A test report with no date, no pressure value or no serial number.
- A signatory with no name or position, an address you cannot find.
- A factory that answers "all our chambers are the same" when you ask for the PS and the volume of the specific model.
When the file is incomplete, there are two outcomes: we order the missing tests from a third-party laboratory, or we rule out the factory. The cost of the tests is shown on the quote.
Customisation changes nothing about these requirements. A shell or cover in your colour, a logo on the shell and the control panel, a rating plate in your branding: these options are described on the White label page. The question of who holds the role of manufacturer in the European sense when the machine is sold under your brand is being validated by a regulatory consultant; we do not settle it in this article.
Maintenance and running costs
Three items come back every year, beyond the purchase price.
| Item | What it includes | Costing |
|---|---|---|
| Energy | Compressor and air conditioning running during the session (60 to 90 minutes) | On request |
| Consumables | Compressor filters, door seals, concentrator molecular sieve, envelope and zips of a soft chamber | On request |
| Checks | Periodic check of the envelope and valves according to the manual, pressure test according to the applicable regulations | On request |
The manual specifies the interval between checks. We hand over the maintenance logbook with the chamber and can put you in touch with an inspection body.
The Directive concerns placing on the market; its Article 3 leaves Member States free to lay down requirements to protect persons when pressure equipment is used. In-service follow-up therefore falls under the rules of each country. Have the in-service inspections required in your country for the selected model, according to its working pressure and volume, confirmed by an inspection body or by the competent authority.
Two commercial data points remain to be confirmed model by model: the length and scope of the warranty (on request) and the availability of spare parts (on request).
The complete maintenance plan, task by task, is developed in maintenance and servicing of a hyperbaric chamber coming soon.
Use in a wellbeing centre: what this article does not settle
The Pressure Equipment Directive answers one question: is this enclosure designed and documented to hold its pressure? It says nothing about what you are entitled to offer your clients, or how to talk about it.
The models we offer are presented as wellbeing equipment for professional use, with no medical purpose claimed. Regulation (EU) 2017/745 defines a medical device by its medical purpose, as stated by the manufacturer on the label, in the instructions or in promotional or sales materials (Article 2, points 1 and 12): a stated medical purpose would therefore change the applicable framework. The status of your centre, the local operating rules and the classification of your offer depend on the country, the model chosen, whether or not oxygen is supplied and the words you use.
We do not settle this point here. It is examined in hyperbaric chambers and wellbeing centres: the regulatory framework coming soon, and it must be validated by a regulatory consultant before opening, for your country and your project.
Asking for a useful quote
Here is what allows us to answer with a firm figure rather than a range.
- The project and the premises: country, target opening date, cabin floor area, floor level, dimensions of the delivery route, power available (230 V or 400 V).
- The configuration: soft or rigid, seated or lying, one or two places, working pressure, options.
- The brand: colour, logo, rating plate.
From these elements, we consult the factories, we request the technical file and the pressure test reports before selecting a model, then we hand you a quote that separates the machine, the options, the customisation, transport, installation and, where relevant, the additional tests.
Two ways to move forward: fill in the quote request, or book an appointment to talk first about the premises and the regulatory framework. The whole range, with the requirements by family, is on the hyperbaric chambers page.