The price of a cryotherapy chamber depends first on its technology (electric, nitrogen or localised), then on its capacity, its target temperature and the level of customisation. The purchase price does not tell the whole story: works on the premises, energy or nitrogen, maintenance and documentation weigh just as much in the decision. A serious quote itemises each of these items, line by line.
By Kryvana · published 27 November 2026 · updated 27 November 2026
What makes up the price of a cryotherapy chamber
The question "how much does a cryotherapy chamber cost" rarely has a single-figure answer. Two chambers that look alike in a photo can differ in their refrigeration unit, their chamber temperature, their capacity and the documentation that comes with them. Before comparing amounts, compare what they cover.
We do not publish prices until they have been validated model by model: on request. Any range we give is to be read as follows: indicative budget excluding transport, installation and local taxes. Quote tailored to your project.
In the meantime, here is what makes the price vary, in order of weight.
The six variables of the purchase price
- The technology. An electric chamber produces its cold with a refrigeration unit. A cryosauna gets it by evaporating liquid nitrogen. The first requires a higher purchase budget; the second is cheaper to buy but depends on a consumable.
- The capacity. An electric chamber comes as a single-person (mono) model or for up to four people (multi-person). The cryosauna and localised cryotherapy are individual equipment.
- The target temperature. An electric chamber operates from −85 °C to −110 °C depending on the model. The power of the refrigeration unit depends on the target temperature and the number of places.
- The power and format of the unit. From 8 to 25 kW for an electric chamber. The unit can be built into the chamber or remote, in a technical room.
- The level of customisation. A logo and a colour from the factory colour chart do not cost the same as a specific housing or an interface adaptation.
- The documentation and testing. A complete technical file, translated manuals and, where necessary, third-party laboratory tests all have a cost. Before comparing two prices, check that these items appear in both.
What the purchase price does not always include
An "ex-works" price covers neither transport, nor customs clearance, nor delivery to the premises, nor commissioning. Nor does it cover the works on your premises: electrical line, ventilation, sound insulation. These items are priced separately: on request.
That is why we think in terms of the full project cost, not the price of a machine. The Cryotherapy page summarises the three families; this article explains how to choose and what to demand.
The three families: electric, nitrogen, localised
The three families available from factories do not meet the same need. The table sets out their typical characteristics.
| Criterion | Whole-body electric chamber | Nitrogen cryosauna | Localised cryotherapy |
|---|---|---|---|
| Cold production | Refrigeration unit, no consumable | Liquid nitrogen vapour | Chilled forced air or CO₂, applied through a nozzle |
| Temperature | −85 °C to −110 °C depending on model | −120 °C to −160 °C, head outside the cabin | Targeted application, depending on the device |
| Capacity | 1 to 4 people | 1 person | 1 person, practitioner present |
| Power supply | 8 to 25 kW, 400 V three-phase | 1 to 3 kW, 230 V | 1 to 2 kW, 230 V |
| Floor area | 6 to 15 m² (chamber and technical room) | 4 to 8 m², plus tank storage | 2 m², mobile on castors |
| Consumable | None | Liquid nitrogen, regular deliveries | Depending on the technology |
| Main constraint on the premises | Dedicated three-phase line | Reinforced ventilation and oxygen detector | See the model's datasheet |
| Indicative range excluding VAT | On quote | On quote | On quote |
The whole-body electric chamber
This is the reference format for a high-footfall centre. The cold is produced by a refrigeration unit: no gas to order, no tank to store. A typical single-person chamber is about 2,350 mm high, 1,200 mm wide and 1,100 mm deep, weighs 450 to 600 kg and requires a 400 V three-phase line at 32 A for 9 to 12 kW. Cooling down at start-up takes 30 to 45 minutes: the chamber is switched on before opening, not between two clients.
The multi-person version takes up to four people per session. It suits a showcase centre or a club that receives groups. Its power and floor-area needs are higher. See the example sheet single-person electric chamber.
The nitrogen cryosauna
The cryosauna is an individual cabin open at the top: the head stays outside the cabin. The cold comes from liquid nitrogen vapour, stored in an insulated tank called a dewar. A typical unit weighs 150 to 250 kg excluding the dewar and plugs into a 230 V 16 A socket.
Its advantage is that it is the entry-level option: cheaper to buy, installed without three-phase. The trade-off is twofold. You depend on a nitrogen delivery contract, and the room must be fitted with ventilation and an oxygen detector. The details are in the example sheet nitrogen cryosauna and in the article Individual cryosauna: how it works, safety, maintenance coming soon.
Localised cryotherapy
The localised cryotherapy device projects targeted cold through a nozzle, using chilled forced air or CO₂. It fits in 2 m², moves on castors and runs on 230 V. A practitioner is present throughout the application. It is clinic or treatment-room equipment, not a flagship piece for a centre. The article Localised cryotherapy: which device for a clinic? coming soon compares the technologies.
Technical selection criteria
Three questions guide the choice: how many sessions a day are you aiming for, do you have a three-phase supply, and are you willing to manage nitrogen deliveries? Above 25 sessions a day, electric is the answer. Below that, the cryosauna remains relevant if the ventilation of the room is feasible.
Beyond that first sorting, here are the criteria to check on each model's datasheet.
- Target footfall. A session lasts 2 to 4 minutes. With welcome and preparation, a single-person chamber handles 8 to 12 sessions per hour, or 60 to 100 sessions a day over a full opening span. If your plan relies on groups, look at the multi-person model.
- The actual chamber temperature. Ask for the range for each programme, and how it is measured (probe positions). A temperature announced without a measurement method cannot be compared.
- Cool-down and holding. How long at start-up, what consumption on standby between two sessions, what behaviour with the door open.
- The refrigeration unit. Built in or remote, compressor make, refrigerant declared on the plate with its charge, noise level.
- Safety devices. Presence detector, door opening from the inside, emergency stop, alarms, the operator's view of the person.
- The interface. Screen language, programmes, ability to rename programmes and show your brand at start-up.
- Maintenance. Inspection intervals, wear parts, parts availability, remote assistance.
- Documentation. EU declaration of conformity, technical file, manual in French: before the order, not after.
The detailed comparison of the two whole-body technologies is in Electric or nitrogen cryotherapy: technical and cost comparison coming soon.
Three purchasing mistakes to avoid
The first: a cryosauna bought without having costed the nitrogen, whose recurring cost was not anticipated. The second: an electric chamber undersized for the number of sessions aimed for. The third: a machine delivered without a usable manual or a technical file.
None of these mistakes shows up in a price. All of them show up in an itemised quote.
Premises requirements
The premises decide a lot: the available power, the possibility of ventilating, the delivery access. Have these points checked before signing a lease, and in any case before ordering.
| Item | Electric chamber | Nitrogen cryosauna |
|---|---|---|
| Electricity | Dedicated 400 V three-phase line, 32 to 63 A depending on power, suitable circuit breaker and residual-current device | 230 V 16 A socket |
| Ventilation | Mechanical extraction sized by the installer | Air renewal and oxygen detector mandatory in the room |
| Floor and load | Level floor, 400 to 900 kg depending on model | Level floor, 150 to 250 kg excluding tank |
| Delivery access | Doorway at least 90 cm wide | Doorway and route for the nitrogen tank |
| Technical room | Built-in or remote unit: 50 cm clearance, condensate drainage | Ventilated place for the dewar, ideally outside the session room |
| Noise | Unit runs continuously: sound insulation if the room adjoins a quiet area | See the model's datasheet |
In a complete centre, the cold area (chamber and technical room) takes up 25 to 35 m². A showcase centre combining a multi-person and a single-person chamber plans for 40 to 60 m².
The availability of three-phase is the first thing to check: without it, the electric chamber cannot be installed. If the electrical panel of the premises cannot supply the power required, the power increase is requested from the network operator, with a lead time and a cost of their own: on request.
Before your works, we provide the power data sheet of the chosen model; the layout plan is included from the Project level. Your electrician and your design office build them into the premises project. The article Installing a cryotherapy chamber: premises requirements coming soon covers each item in detail.
Running costs to anticipate
The purchase price is paid once. Running costs are paid every month, throughout the life of the machine. They are what separates an electric chamber from a cryosauna.
The energy use of an electric chamber
An electric chamber consumes in two ways: during sessions, and keeping cold between sessions. The second is often forgotten. A chamber that stays cold all day for ten sessions does not have the same cost per session as one that receives eighty.
We do not publish an average consumption: it depends on the model, the setting and your footfall. Ask the supplier for both values, in writing, with their measurement conditions.
The nitrogen of a cryosauna
Liquid nitrogen is a running cost in its own right. It includes the gas used per session, the tank (rental or purchase) and the delivery charges. The price is negotiated with a local gas supplier, under contract.
One point of vigilance: ask the gas supplier, in writing, for any tank losses between two deliveries, and include them in your calculation.
Maintenance, parts and insurance
An electric chamber requires an annual check of the refrigeration unit and the sensors, cleaning of the sensors and door seals, and a check of the presence detector. A cryosauna requires a check of the hoses, valves and oxygen detector, as well as a log of nitrogen deliveries.
If the refrigeration unit contains a fluorinated greenhouse gas, Regulation (EU) 2024/573 may concern it. Its Article 12 provides that refrigeration equipment containing these gases carries a label showing the gas, its quantity by weight and in CO₂ equivalent, and its global warming potential. Its Article 5 requires operators and manufacturers to ensure leak checks for equipment containing 5 tonnes of CO₂ equivalent or more of certain of these gases; hermetically sealed equipment labelled as such is exempt below a threshold of 10 tonnes of CO₂ equivalent. So ask for the fluid and its charge before buying, and have your refrigeration engineer check whether a checking obligation could fall to you.
Finally, add the operator's time, present at every session, and insurance. Your insurer may ask for the manual and the compliance documentation of the machine: keep them to hand.
From cost per session to the business plan
Once these items are known, bring them down to a cost per session, then test several footfall levels. Our profitability simulator is made for this. Indicative simulation based on your assumptions. It is neither a promise of results nor financial advice.
The full method is described in Energy use and running costs of a cryotherapy chamber coming soon.
Safety: nitrogen, cold and procedures
The safety of a chamber rests on four elements: the machine, the premises, the procedure and the operator. None replaces the others.
Nitrogen and the oxygen detector
As it evaporates in a closed room, nitrogen can lower the share of oxygen in the air. The properties of the gas and the preventive measures are set out in its safety data sheet, to be requested from the gas supplier. That is why a cryosauna requires two pieces of equipment in the room: air renewal sized by the installer, and an oxygen detector with an alarm.
The tank is stored in a ventilated room, ideally outside the session room. The nitrogen safety data sheet and the storage instructions are among the documents to receive. The oxygen detector is checked at the interval given in its manual, and this check is recorded in the maintenance log.
Cold and the operator
Whatever the technology, cryotherapy requires a trained operator, present during the session. The duration of a session is short (2 to 4 minutes on the example electric chamber, 2 to 3 minutes on the example cryosauna) and it is respected. The instructions on supervision, welcome and clothing come from the manufacturer's manual, not from habit.
The operator makes no diagnosis. If in doubt about a client's situation, your intake questionnaire refers them to a healthcare professional. The article Cryotherapy chamber safety: sensors, procedures, ventilation coming soon details the sensors and procedures.
To read the studies with their limitations, see Whole-body cryotherapy: what research says, what we cannot promise coming soon.
Documentation to demand before paying
A cryotherapy chamber is electrical equipment. In principle it falls under the Low Voltage Directive 2014/35/EU, which applies to equipment designed for use with a rated voltage between 50 and 1,000 V for alternating current, subject to the exclusions in its Annex II. Other texts apply depending on its design: Electromagnetic Compatibility Directive 2014/30/EU, RoHS 2011/65/EU, Radio Equipment Directive 2014/53/EU if the chamber includes Wi-Fi or Bluetooth, and the Machinery Directive 2006/42/EC, then Regulation (EU) 2023/1230 applicable from 20 January 2027, for motorised moving parts. We list the texts; we do not state that a specific model complies with them before having its file in hand.
Our commitment fits in one sentence: we check and complete the compliance documentation of every piece of equipment before shipment.
The documents to receive
- The EU declaration of conformity, signed, in the manufacturer's name, with the texts and standards cited.
- The technical file, or a statement that it is available: wiring diagrams, list of components, test reports.
- Third-party laboratory reports, where they exist or have been commissioned.
- The user and maintenance manual in French, and in the languages of the country of delivery.
- The labelling: rating plate, safety pictograms, refrigerant and its charge.
- For a cryosauna: the nitrogen safety data sheet and the storage instructions.
What the directive requires of the importer
Article 8 of Directive 2014/35/EU sets the obligations of whoever imports the equipment into the Union. Before placing it on the market, the importer ensures that the manufacturer has carried out the conformity assessment procedure and drawn up the technical documentation. The importer indicates their name and postal address on the equipment, or failing that on the packaging or an accompanying document. They ensure that the equipment is accompanied by instructions and safety information in a language easily understood by users. They keep a copy of the EU declaration of conformity at the disposal of the authorities for ten years.
Practical consequence: if you buy alone, directly from a factory outside the Union, some of these obligations may fall to you; have your role checked by an adviser before ordering. If you go through an importer, ask them to show you that they fulfil them. The full allocation of roles between factory, importer and operator is on our Compliance page.
Warning signs
- A "CE certificate" issued by a laboratory: CE marking rests on a declaration by the manufacturer, not on a certificate, except under particular procedures.
- Standards cited without an edition number, or directives repealed years ago.
- A signatory with no name or position, an address that cannot be found, an undated document.
- A "generic" document covering the whole range with no model reference.
- A test report whose laboratory refuses to confirm that it issued it.
Customisation: a chamber under your brand
The cryotherapy chamber is the most visible piece of equipment in a recovery centre. Having it produced under your brand, rather than the factory's, keeps your identity consistent throughout the venue. Here is what can be done on a cryotherapy chamber.
- The outer housing in your RAL colour, the logo on the door and the front panel.
- The start-up screen and the programme names, where the factory allows it.
- The rating plate in your brand.
- A branded product photo kit for your communication.
The Standard level (logo, colour from the factory colour chart, plate) fits within the production lead time. The Advanced and Bespoke levels can extend it and sometimes require a minimum quantity set by the factory: on request.
The sequence is always the same. You supply a vector logo and your colour codes. We check with the factory what is feasible on the chosen model. You receive a proof, and your written approval triggers production. Before shipment, we compare the machine with the proof, with photos as evidence. The detail of the levels is on the White label page.
One point to know: Article 10 of Directive 2014/35/EU provides that an importer or distributor who places electrical equipment on the market under their own name or brand is considered a manufacturer. Who carries that role when the chamber is under your brand remains to be validated by a regulatory consultant: on request.
What a quote must contain, and the questions to ask
A quote that fits on one line ("cryotherapy chamber, total price") allows no comparison. Demand the detail below, from us as from any other supplier.
| Quote line | What must appear |
|---|---|
| Machine | Model reference, capacity, temperature range, power, voltage, dimensions, weight |
| Customisation | Level chosen, items branded, proof included or not |
| Documentation | List of documents supplied, manual languages, third-party tests planned and their cost |
| Transport | Mode, Incoterm, customs clearance, delivery to the premises or to the port |
| Installation | Commissioning, team training, what remains for your electrician |
| Warranty and after-sales | Duration, parts covered, parts dispatch time, remote assistance |
| Schedule | Production and transport lead times, target commissioning date |
| Payment | Deposit, instalment schedule, balance terms |
Our own terms will be shown as soon as they are validated: on request.
Twelve questions to ask the supplier
- What is the exact model reference, and who is the manufacturer?
- What is the temperature range for each programme, and how is it measured?
- What is the consumption per session and when holding the cold, under what measurement conditions?
- Which refrigerant, in what quantity? Is it shown on the plate?
- What safety devices does the chamber have, and how are they tested?
- Can I receive the EU declaration of conformity and the summary of the technical file before ordering?
- Is the manual in French? Can I read it before buying?
- Who is the importer in the Union, and where do they keep the documentation?
- Which wear parts should be planned for, at what price, with what dispatch time?
- Who installs, who trains my team, and what remains for my electrician?
- What does the warranty cover, and what happens if the refrigeration unit fails?
- For a cryosauna: which oxygen detector is provided, and what nitrogen consumption per session do you state in writing?
A serious supplier answers these questions in writing. A vague answer on points 6 to 8 is enough to rule them out.
From quote to commissioning
With us, a chamber project always follows the same order. A thirty-minute discovery call sets out the project, the premises, the budget and the schedule. The study defines the machine's requirements in your premises. We then compare two to three factories per family, on datasheets, and you receive a comparison table with an itemised quote. Next come customisation and its proof, production with an end-of-line check, verification of the documentation, then delivery, installation and training depending on the level chosen.
Three levels of support exist. Essential covers the machine, its documentation and its delivery. Project adds the layout plan, installation and training. Turnkey adds the business plan, the price list and follow-up after opening. What is included and what is optional is written down before the order.
If your premises and target footfall are known, you have what you need to obtain a precise quote. State them in your quote request: technology envisaged, available power, floor area of the cold zone, number of sessions per day aimed for, customisation level. You will receive a line-by-line quote, with the list of documents supplied.