- Sheet
- KRV-BAIN-CIRCUIT-
- Family
- Cold plunge baths
- Status
- Example sheet
- Rev.
- A
Two-person hot / cold contrast circuit
Cold bath at 3 to 6 °C and hot bath at 38 to 40 °C side by side, separate units, filtration per basin: the contrast area of a full centre.
- Indicative price excl. VAT
- specified in the quote
- Lead time
- specified in the quote
- Warranty
- specified in the quote
- Family
- Cold plunge baths
- Example sheet
- Typical specifications: the exact model and its values are confirmed in the quote.
Indicative budget excluding transport, installation and local taxes. Bespoke quote.
Datasheet
typical specifications| Dimensions | 2 tanks L 2,000 × W 1,200 mm (typical) |
|---|---|
| Weight | 1,800 kg with water (both tanks) |
| Power supply | 400 V three-phase |
| Power | 6 to 9 kW |
| Capacity | 2 + 2 people |
| Cold bath | 3 to 6 °C, 800 L |
| Hot bath | 38 to 40 °C, 800 L |
| Filtration | independent per basin |
| Disinfection | UV or chlorine depending on the model |
Available customisation
RAL or wood cladding
Aprons logo
Displays in your branding
Documentation supplied
- EU declaration of conformity checked before shipment
- Technical file available on request
- Operating and maintenance manual in French
- Labelling and rating plate in your branding
Installation and maintenance
Installation requirements
Waterproofed wet area, 400 V, water supply and drainage per basin, ventilation against condensation.
Maintenance
Cleaning of tanks and filters, disinfection, annual check of both units.
Frequently asked questions
What surface area is needed?
10 to 20 m² in a wet area, with circulation space and showers.
What structure is needed?
Nearly two tonnes with water: a structural engineering firm is recommended on an upper floor.
What maintenance is needed?
Two hygiene plans, one per basin, with planned water renewal.
Request a quote for this model
Tell us which families interest you: we come back with a comparison of factories and a first estimate.
KRV · 03.04.C/12