IHHT machine: how it works and how to choose a system
An IHHT machine delivers, through a mask, air whose oxygen content alternates between a reduced phase and an enriched phase, in programmed cycles and under the monitoring of a pulse oximeter. Choosing a system comes down to documented sensor accuracy, lockable safety thresholds, the software, maintenance and the compliance documentation. It is wellbeing equipment for professional use, run by a trained operator.
By Kryvana · published 27 November 2026 · updated 27 November 2026
What an IHHT machine does, technically
IHHT stands for Intermittent Hypoxia-Hyperoxia Training. The person sits in an armchair, at rest, and breathes through a mask air whose oxygen content changes over the course of the session.
Two phases alternate. In the reduced phase, the air delivered contains less oxygen than ambient air: typically 9 to 15% O₂ on our example sheets. In the enriched phase, it contains more: up to 30 to 40% O₂. The machine alternates these two phases in programmed cycles. A session generally lasts 30 to 45 minutes.
Throughout the session, a pulse oximeter measures oxygen saturation (SpO₂) and shows it on screen. This measurement is not just a display: it drives safety. If saturation falls below the configured value, the reduced phase stops.
When buying, the quality of a system therefore comes down to four things: what it actually delivers, what it measures, what it locks, what it records.
The protocols (phase durations, number of cycles, who is admitted) are defined by the operator of the centre, not by the machine or by us. And this page makes no promise about the effects of a session: the box further down explains why.
The components of an IHHT system
Factory datasheets look alike. To compare them, break them down component by component and ask, for each one, for the measured figure rather than the claimed one.
The reduced-oxygen air generator
This is a membrane hypoxic generator: ambient air passes through membranes that change its composition. It is the part that sets the low end of the machine's range. Membranes are wear parts: their replacement is set out in the manual, and it is one of the first lines to have priced.
The oxygen concentrator
It produces the enriched air for the second phase. It works with a sieve, which is also among the consumables of the family. Ask the factory for the content actually delivered at the mask, not the content at the concentrator outlet: between the two there is a circuit, fittings and a flow rate.
The mask and the breathing circuit
The mask and the oximeter sensor are the parts in direct contact with the person. Two set-ups exist: an individual mask per customer, or a shared mask fitted with a disposable filter. In both cases, a disinfection protocol between users has to be written. Check that masks and filters are available in several sizes, and above all how they are resupplied: a centre that can no longer order its filters stops its sessions.
The sensors
Two measurements matter. The first is the oxygen content of the air delivered. The second is the person's saturation, from the pulse oximeter. The sensor accuracy sheet is one of the documents we ask for in this family: it states the accuracy on delivered O₂ and on SpO₂, along with the safety thresholds.
A sensor drifts over time. Periodic calibration is therefore a normal maintenance operation, to plan from the purchase: who does it, with what tool, how often.
The software and the control screen
The software sequences the cycles, displays the measurements and applies the thresholds. On a compact unit, it is limited to a control screen. On a professional station, it manages profiles, a history and an export, for several users.
During a demonstration, check three points: the locking of the thresholds (and who can unlock them), the interface and alerts in French, the export and where histories are stored.
The last point matters: a session history linked to a person is personal data, to be handled in line with the GDPR.
Two formats: compact unit or professional station
Two formats leave the factory. The principle is the same; what changes is the breadth of the ranges, the software and the number of stations. The values below are those of our example sheets: they give an order of magnitude and are confirmed model by model on the quote.
| Criterion | Compact tabletop unit | Professional station |
|---|---|---|
| Technology | Membrane hypoxic generator, concentrator, mask, pulse oximeter, control screen | Same principle, extended ranges, multi-user tracking software, mobile frame |
| Capacity | 1 person | 1 person, up to 2 stations depending on the model |
| Reduced range | 9 to 15% O₂ (typical) | Extended, depending on the model |
| Enriched range | Up to 30 to 40% O₂ (typical) | Extended, depending on the model |
| Power | 0.5 to 1 kW, 230 V | 1 to 2 kW, 230 V |
| Dimensions (typical) | W 500 × D 400 × H 350 mm | W 600 × D 500 × H 1,100 mm |
| Weight | 15 to 25 kg | 40 to 60 kg |
| Floor area | 2 to 3 m² (armchair and unit) | 3 to 5 m² |
| Software | Control screen, programmes | Profiles, history, export |
| Indicative range excl. VAT | On request | On request |
Indicative budget excluding transport, installation and local taxes. Tailored quote.
When the compact unit is enough
The compact IHHT unit suits a practice, a studio or a centre that adds a service in an existing cubicle that is quiet and ventilated. It sits on a table or a side unit, next to an armchair. One station, so one person at a time: your capacity is simply worked out from the session length and the disinfection time between two customers.
When the station is justified
The professional IHHT station is aimed at a club or a centre that follows its customers over time. The mobile frame lets you move it from one cubicle to another. The multi-user software keeps a history for each profile. And the second station, when the model offers one, lets one operator supervise two people at the same time.
If you plan neither a history nor a second station, the gap with the compact unit narrows, on our example sheets, to the extended ranges and the mobile frame.
How a session runs and the role of the operator
IHHT is a supervised service. The requirements for the family are explicit: a trained operator is present during the session, and the safety thresholds are configured and locked. This has two direct consequences for your project: a staff cost per session, and a need for training before opening.
A typical session runs as follows, on the operating side:
- Welcome the person and settle them in the armchair.
- Fit the mask (individual, or shared with a new filter) and the pulse oximeter.
- Select the programme and check the thresholds, by the operator.
- Run the cycles, 30 to 45 minutes, with the operator keeping the screen in view.
- End of session, mask removal, recording of the session if the software provides for it.
- Disinfection according to the protocol, filter replacement.
What the operator must be able to do
- Set a programme and read the measurements displayed.
- Configure and lock the safety thresholds, and know what the machine does when a threshold is crossed.
- Stop a session at any time.
- Apply the hygiene protocol for the mask and the circuit.
- Recognise an inconsistent measurement (sensor badly placed, sensor needing calibration).
With us, training of the team (settings, thresholds, hygiene, running a session) is included in the Project and Turnkey levels of support. At the Essential level, it is offered as an option.
What is the operator's responsibility, not the machine's
The equipment does not decide who may take a session. Before ordering, ask the factory what the model's manual says about situations where use is not recommended. The questionnaire beforehand, and the cases where a session is refused or subject to medical advice: all of this is part of your own procedures, to be written with a doctor before opening and communicated to every operator. At the Turnkey level, we supply a template of welcome and session protocols (welcome, running order, hygiene): the phase durations and the number of cycles remain yours, it replaces neither the manual nor that advice, and we publish no list of contraindications.
Selection criteria for a system
On this family, two elements set a professional station apart from a consumer product: the sensor accuracy sheet and the list of lockable safety thresholds. We only keep factories that document both. Here is the full grid.
- Documented sensor accuracy. An accuracy value for delivered O₂ and for SpO₂, written on a sheet, with the measurement method. A mention of "high accuracy" with no figure is worth nothing.
- Lockable safety thresholds. The list of thresholds, their default values, who can change them, and what the machine does when a threshold is reached.
- Ranges actually delivered. The reduced and enriched ranges measured at the mask, not calculated.
- Software. Language, profiles, history, export, updates. And where the data is stored.
- Number of stations. One or two, with what the second station changes for power, floor area and supervision.
- Consumables. References, availability in Europe, compatibility with standard or proprietary masks and filters.
- Maintenance. Calibration, membranes, sieve, filters: frequency, downtime, and whether your team can do it or not.
- Noise and heat. The generator and the concentrator run throughout the session, in a room that has to stay quiet. Ask for the measured noise level.
- Documentation. EU declaration of conformity, manual in French, labelling: see below.
- Parts and after-sales. Which parts are held in stock, and how quickly they ship.
The questions to ask, and the proof to obtain
| Question | Proof expected | Warning sign |
|---|---|---|
| What accuracy on delivered O₂ and SpO₂? | Sensor accuracy sheet, with method | No figure given |
| Which safety thresholds, lockable by whom? | List of thresholds and screenshots of the locking menu | Thresholds that any user can change |
| What does the machine do below the saturation threshold? | Filmed demonstration of the reduced phase being interrupted | A simple audible alarm with no change of phase |
| What ranges at the mask? | Measurement record on the exact model | Ranges copied from another model |
| Who calibrates the sensors, and how? | Procedure in the manual, tool supplied or service offered | "No calibration needed" |
| What lifespan for the membranes and the sieve? | Value from the manual, price of the part | Verbal answer, not in writing |
| Are the consumables standard? | References and alternative suppliers | Proprietary consumable with no stock in Europe |
| Does the EU declaration cover this model? | Declaration in the manufacturer's name, model reference, texts cited | Certificate for another product or another company |
Room requirements
IHHT is one of the least demanding families for the building. No nitrogen, no water, no three-phase supply, no reinforced slab.
| Item | What to plan for |
|---|---|
| Electricity | 230 V 16 A, standard socket |
| Room | Quiet, ventilated room, reclining armchair, soft lighting; no wet area needed |
| Floor area | 2 to 3 m² for a compact unit, 3 to 5 m² for a station (two armchairs for a two-station model) |
| Consumables and hygiene | Individual masks or disposable filters, disinfection protocol between users, clean storage |
| Supervision | Trained operator present during the session, safety thresholds configured and locked |
A few practical points, which appear on no datasheet but decide how comfortable the operation is:
- Quiet. The session takes place at rest, for 30 to 45 minutes. A cubicle next to a noisy studio or a plant room gives a poor experience. Acoustics are sorted out at the plan stage, not afterwards.
- Ventilation. The room must be ventilated: it is a requirement of the family. Ask the factory what the model's manual requires precisely (air renewal, clearance around the unit, precautions linked to oxygen-enriched air) and carry it onto the plan.
- The operator's position. They must see the screen and the person at the same time. On a two-station unit, place the two armchairs in the same field of view.
- Storage. Masks, filters, disinfection products: a closed cabinet within reach.
In a complete project, IHHT goes in a dry cubicle. In our Complete Centre pack, it shares the cubicle area with the hyperbaric chamber, LED, pressotherapy and PEMF. For a club, our sports clubs page fits it into a 100 to 250 m² layout with cryotherapy, the contrast circuit, diagnostics and pressotherapy.
Consumables, maintenance and running costs
The machine uses little energy: it only runs during the session, at a power of 0.5 to 2 kW depending on the format. The real running cost lies elsewhere: consumables, maintenance of the sensors and membranes, and the operator's time.
We publish no running figure until it has been confirmed in writing by the factory for a specific model. Here are the cost lines, and what is still to be supplied.
| Item | Nature | Figure |
|---|---|---|
| Energy | Unit running during a 30 to 45 minute session | On request |
| Masks and filters | Individual masks or disposable antibacterial filters | On request |
| Concentrator sieve | Wear part | On request |
| Membranes | Replacement as set out in the manual | On request |
| Sensor calibration | Periodic operation | On request |
| Software | Updates | On request |
Three tips to avoid discovering these costs after opening.
Have a full year of operation priced, not just the machine. Give the factory your assumption for sessions per week and ask for the list of corresponding consumables and parts. A machine that is cheaper to buy can cost more to run if its filters are proprietary.
Order a starter stock. Masks, filters, a set of wear parts. For the models we deliver, a stock of critical parts is built up, and parts ship by express.
Keep a maintenance log from commissioning. Calibration date, membrane change, sieve change, filter change, software version.
Documentation and regulatory classification
The documents supplied with the machine
For this family, the file we ask the factory for includes:
- the EU declaration of conformity (low voltage, EMC, RoHS; radio if the device has connectivity);
- the sensor accuracy sheet (delivered O₂, SpO₂) and the safety thresholds;
- the manual in French: installation, cleaning protocols, membrane maintenance;
- the labelling: power, oxygen ranges, pictograms.
If the device is classified as wellbeing equipment, the texts involved are those of an electrical appliance: the Low Voltage Directive 2014/35/EU, which covers equipment with a voltage rating of between 50 and 1000 V for alternating current (Article 1) and excludes from its scope electrical equipment for medical purposes (Annex II); the Electromagnetic Compatibility Directive 2014/30/EU; the RoHS Directive 2011/65/EU; the Radio Equipment Directive 2014/53/EU if the model communicates over Wi-Fi or Bluetooth. Our compliance page also cites, for all equipment, Regulation (EU) 2023/988 (General Product Safety Regulation) and the professional WEEE stream: how they apply is checked model by model and by use. Finally, ask the factory whether the circuit includes a pressurised element: the question is then examined with the consultant.
Our commitment is as follows: we check and complete the compliance documentation of every piece of equipment before shipment. We do not state here that any given model complies with any given text; the detail is on our compliance page, with the "who does what" table between the factory, the importer and you.
Wellbeing equipment or medical device
This is the most sensitive question for this family, because the machine delivers modified air and measures a saturation.
The systems we offer are presented as wellbeing equipment for professional use, with no medical purpose. Regulation (EU) 2017/745 defines a medical device by its purpose: the intended purpose is the use for which a device is intended according to the data supplied by the manufacturer on the label, in the instructions for use or in promotional or sales materials or statements (Article 2(1) and (12)). Among the medical purposes it lists is the investigation, replacement or modification of a physiological process or state. A promise of an effect on the body, in a brochure, on a website or in a sales pitch, can therefore change the applicable framework.
That Regulation also applies to the groups of products without a medical purpose listed in its Annex XVI (Article 1(2)). We do not rule here on the case of an IHHT machine: the classification is validated by a regulatory consultant, before the order, for the exact model and for the use you announce.
Two practical rules follow:
- your materials talk about wellbeing, recovery, comfort, experience and technical data, never about a result on the body;
- your operators do not comment on a saturation reading as a healthcare professional would. The measurement is used to run the session, not to give an opinion on the person's condition.
Session data
A station that records profiles and histories handles personal data. The GDPR protects data concerning health more strictly (Article 9), meaning data that reveal information about a person's state of health (Article 4(15)). The CNIL points out that this notion is assessed case by case and can cover measurement data from which information about a person's state of health is inferred. Saturation readings linked to a person may therefore fall within it. Have this point validated before switching on the history: customer information, retention period, hosting location, operators' access rights.
Budget, lead time and white label
The price
The ranges for the family have not yet been published: on request. They will be indicative excl. VAT, excluding transport, installation and local taxes, and refined by a tailored quote.
To compare two offers, think in terms of full cost:
- the machine, with its number of stations;
- the armchair or armchairs, included or not depending on the offer;
- the starter stock of masks, filters and wear parts;
- transport, customs clearance, commissioning;
- training of the team;
- a year of consumables and maintenance;
- the regulatory validation if it is not included.
Lead time and warranty
Production and delivery lead time: on request. Warranty period and scope: on request. On this type of device, read above all what the warranty says about the sensors and the membranes: they are the parts that wear.
Customisation to your brand
An IHHT machine can be customised on three points: the unit cover in your RAL colour, your logo on the frame and on the welcome screen where the firmware allows it, and the programme names depending on the software. The labelling and the rating plate can carry your brand. Putting your brand on a device can have consequences for the roles and responsibilities under European texts: this point is being validated by a regulatory consultant and is addressed before any white label order.
To receive a costing for your case (format, number of stations, level of support, country of delivery), the quote form takes a few minutes.
IHHT among the other technologies in a centre
IHHT generally complements an offer, and it helps to place it against the other compact equipment in a centre. All run on 230 V and take up little space; EMS also needs a water point to dampen the suits. They differ mainly in their operating requirements, taken here from the sheet for each family.
| Family | What the equipment does | Operating requirements | Point to watch |
|---|---|---|---|
| IHHT | Delivers air of variable oxygen content through a mask, under a pulse oximeter | Trained operator present during the session, thresholds configured and locked | Sensors, thresholds, regulatory classification |
| PEMF | Emits low-frequency magnetic pulses through a mat, chair or applicators | Contraindications of use from the manual displayed and checked at welcome | Intensity and frequencies measured and documented |
| Full-body EMS | Pulse generator and electrode suit | Trained coach present; manufacturer's contraindications of use checked before the first session | Hygiene of the suits, classification depending on the stated purpose |
| Pressotherapy | Inflates the chambers of boots, belt or sleeves in sequence | Manufacturer's contraindications of use displayed and checked at welcome | Hygiene of shared accessories |
| Diagnostics | Measures body composition, aerobic capacity, heart rate variability | Trained operator; VO2max test under supervision following the manufacturer's instructions | Personal data, no medical interpretation |
Each family has its article in this series:
- professional PEMF coming soon, to compare mats, chairs and multi-applicator systems;
- opening a full-body EMS studio coming soon, the equipment most tied to the coach;
- professional pressotherapy coming soon, supplementary equipment that takes up little space;
- choosing a body composition analyser coming soon;
- building a diagnostic offer with VO2max and HRV coming soon, to be considered alongside an IHHT station with a history;
- the vacuum infrared treadmill coming soon, to be viewed with some distance;
- fitting out a salt room coming soon, a bespoke fit-out more than a piece of equipment.
What to pair IHHT with
IHHT and diagnostics have similar requirements: a quiet room, a trained operator, software, personal data to protect.
IHHT and staff. During an IHHT session, the operator keeps the screen and the person in view. For the other equipment in the cubicle, read the operating requirements on each sheet and each manual: these, together with the number of stations supervised, decide the staff to plan for.
Before asking for a quote
Gather six items, and your quote will be quicker and more precise: your profile and your country of delivery; the number of sessions targeted per day; the format (compact unit or station, one or two stations); the room planned and who will be the operator; the follow-up wanted, with or without a history per customer; the customisation and the level of support.
The IHHT family page covers the two formats, the requirements and the documentation. After the discovery call and the study, you receive a comparison of models, with the documentation available for each and what remains to be validated before the order: we prefer a line saying "to be confirmed" to a figure the factory has not put in writing.