Professional LED light therapy bed: price and selection criteria
A professional red LED bed is chosen on measured data, not on a number of diodes: wavelengths emitted, irradiance at a known distance for each one, illuminated surface, electrical power and photobiological safety classification. Its price depends on the format, the power, the customisation and the documentation required, and it is set by quote. Before any order, the regulatory qualification of the model should be validated by a consultant, because some light-based devices fall under Annex XVI of Regulation (EU) 2017/745.
By Kryvana · published 27 November 2026 · updated 27 November 2026
What a professional red LED bed is
A professional LED light therapy bed is a piece of equipment with a canopy and a mattress fitted with diodes, in which the client lies down for a session of 10 to 20 minutes. The diodes typically emit in two zones of the spectrum: visible red (630 and 660 nm) and near infrared (810 and 850 nm), which is invisible to the eye.
On paper, all beds look alike. In practice, this is the family of equipment whose data sheets are the hardest to compare: irradiance quoted without a measurement distance, approximate wavelengths, electrical power mistaken for optical power. Two beds sold with the same sales pitch can have nothing in common once measured.
This article follows the order of a purchasing decision:
- choose the format (bed, panel or standing booth) according to space and session throughput;
- read the data sheet without falling into traps;
- check that the premises can cope (power supply, heat, floor);
- check photobiological safety and documentation;
- have the regulatory framework validated before signing;
- understand what the price is made of.
It describes no effect of the sessions on the body. This choice is deliberate, it is explained below, and it protects you as much as it protects us.
Whole-body bed, panel or standing booth: three formats, three uses
The bed and the panel use the same wavelengths; for the standing booth, they are checked model by model. What changes is the client's position, the floor area occupied, the power to bring in and the place of the device in your client journey.
| Criterion | Whole-body bed | Wall or floor-standing panel | Standing booth |
|---|---|---|---|
| Principle | LED canopy and mattress, session lying down | Adjustable LED modules, session standing or seated | 360° LED walls, short standing session |
| Capacity | 1 person | 1 person | 1 person |
| Electrical power | 1.5 to 4 kW | 0.3 to 1.5 kW | 2 to 5 kW |
| Power supply | 230 V or 400 V | 230 V | 400 V |
| Floor area to plan for | 6 to 8 m² | 2 to 4 m² | 4 to 6 m² |
| Indicative budget excl. VAT | By quote | By quote | By quote |
These values come from our LED light therapy page. They describe families of devices, not a specific model.
The whole-body bed
The bed is the format that is easiest for the end client to understand: a dedicated booth, a session lying down, both sides of the body exposed without changing position. It is also the most demanding for your premises: 6 to 8 m², a weight of 150 to 300 kg, and several kilowatts of power to supply and then to remove as heat. The example sheet for the whole-body LED bed gives a typical size of 2,100 × 900 × 1,100 mm.
The wall or floor-standing panel
The panel costs less, fits in 2 to 4 m² and plugs into a 230 V 16 A socket. It can be added to an existing booth. The example sheet for the floor-standing LED panel describes a panel of 25 to 45 kg, adjustable in height and tilt. Several panels can be installed in a booth or facing each other, provided the total power and the ventilation are checked. The detailed comparison is in LED panel or whole-body bed coming soon.
The standing booth
The standing booth lights the client from all sides (360°) during a short session. It takes up less floor area than a bed (4 to 6 m²) but needs a 400 V supply and 2 to 5 kW of power. It suits venues where the client passes through quickly and where throughput matters more than the comfort of lying down.
How to decide
Three questions are enough to rule out a format:
- Space. Without a 6 m² room available, the bed is out.
- Electricity. Without 400 V in the premises, the standing booth and high-power beds mean works.
- Client journey. A service sold on its own justifies a bed; a service added to an existing treatment is satisfied with a panel.
Reading a data sheet: wavelengths, irradiance, dose
Our rule is simple: require three figures before any quote. Irradiance at 10 cm for each wavelength, total electrical power, photobiological classification. Without these data, the sheet cannot be compared and we do not commit to an order.
Wavelengths
630 and 660 nm are in visible red. 810 and 850 nm are in the near infrared. A serious data sheet does not just list these values: it states the power or irradiance for each wavelength. "630 / 660 / 810 / 850 nm" without a breakdown does not say whether the device emits mostly red, mostly infrared, or a marginal share of one of the four. Also ask how the wavelength was checked: a nominal value from a diode catalogue is not a measurement on the finished device. The detail is developed in reading the wavelengths on a data sheet coming soon.
Irradiance
Irradiance is the light power received per unit of surface. It is expressed in mW/cm² and only makes sense at a given distance: the further you move from the source, the lower it gets. An irradiance without a measurement distance cannot be compared. We require the measurement at 10 cm, for each wavelength.
Four checks to make on this figure:
- The distance. A value measured in contact with the diodes flatters the sheet and does not match the client's real position.
- The measurement point. A value taken at the centre of the panel says nothing about the edges. Ask for several points, or an average value over the illuminated surface.
- The instrument. Ask for the type of measuring device and the conditions of the reading. A sheet that cannot answer this question has probably not been measured.
- Consistency with the manual. The usage distance stated in the manual must be consistent with the distance at which the irradiance was measured.
Electrical power is not light power
A 4 kW bed draws 4 kW at the meter. That does not mean it delivers 4 kW of light: part of the energy becomes heat in the diodes, the electronics and the fans. Electrical power is used to size your installation, not to judge the device.
The dose
The dose received during a session is expressed in joules per square centimetre (J/cm²). It is calculated by multiplying irradiance by exposure time: an irradiance in W/cm² multiplied by a time in seconds gives J/cm². Two practical points:
- a dose quoted without irradiance or duration cannot be verified;
- the session duration remains the one in the model's manual: the dose is used to compare sheets, not to set a session.
We publish no "recommended" dose value: that would suggest a result. The comparison method is detailed in irradiance and dose: comparing two devices honestly coming soon.
Warning signs on a data sheet
| What the sheet says | What to ask for |
|---|---|
| Irradiance without a distance | The measurement at 10 cm, for each wavelength |
| List of wavelengths without a breakdown | The power or irradiance of each wavelength |
| Number of LEDs or "power" in watts alone | The measured irradiance and the total electrical power at the meter |
| "Safe for the eyes" | The photobiological safety report and the risk group |
| Stated LED lifetime | The measurement condition and the availability of spare modules |
| Mention of an effect on the body | Nothing: it is a reason to drop the supplier or rewrite the sheet |
Power supply, heat and premises
An LED bed needs no water and no consumables. It needs electricity, and it gives that electricity back to the room as heat. These are the two points to anticipate.
The power supply
| Item | What to plan for |
|---|---|
| Electricity | 230 V 16 A for a panel; dedicated 400 V line for a high-power bed or booth |
| Ventilation and heat | Air conditioning or extraction for the room, sized to the installed power |
| Eye protection | Goggles supplied with the device, instruction displayed |
| Floor | Bed: 150 to 300 kg; washable floor |
Before ordering, have your electrician check three points: the voltage available in the premises (230 V only or 400 V), the subscribed power in relation to your other equipment, and the routing of a dedicated line to the booth. A high-power bed delivered to premises without 400 V stays in its crate.
Heat
LEDs dissipate heat. A bed of 1.5 to 4 kW means up to several kilowatts to remove from a closed booth of 6 to 8 m² for the whole duration of the sessions. Without air conditioning or extraction sized for this power, the room temperature rises from session to session and the client's comfort deteriorates.
Plan the ventilation at the layout stage, not after delivery. The question also arises when several panels are installed in the same booth.
Consumption
The consumption of a session depends on the electrical power of the model and on the duration, 10 to 20 minutes. We do not publish a cost per session until the data for the selected model are supplied: on request. The full reasoning (voltage, power, heat) is in LED bed consumption coming soon.
Maintenance and lifetime
Routine maintenance is limited to cleaning the optics and the mattress and checking the fans. The LED modules are replaceable. The LED lifetime stated by the factory has to be verified: on request.
Photobiological safety: what to require
A device that emits visible and infrared light close to the body raises a safety question for the eyes and the skin. That question is settled by a test, not by a sales sentence.
The report and the risk group
The photobiological safety of a device is assessed under a standard that sorts light sources into risk groups. This classification determines the manual's instructions, the labelling and the wearing of goggles. Have your regulatory consultant confirm the exact reference and the current edition of this standard for your model.
What you should receive, for the exact model you are buying:
- the photobiological safety report, with the classification of the device;
- the labelling: wavelengths, power, risk group;
- the manual in French, with the eye protection instructions and the exposure times;
- the protective goggles, supplied with the device.
A report drawn up for another model, for a single diode or for an earlier version of the device is not valid for yours. Check the model reference, the date and the identity of the laboratory. The subject is developed in photobiological safety of LED devices coming soon.
In your centre
The classification concerns you directly as the operator. Use in line with the manual, staff training and display of the instructions are your responsibility. In practice:
- goggles are handed to every client, and the instruction is displayed in the booth;
- the programmed session duration respects the exposure times in the manual;
- your staff know the manual's instructions, including what to do if a client takes off their goggles or reports discomfort;
- the precautions and contraindications are set out in the model's manual; any health question from a client is a matter for their doctor.
Your staff may also be exposed over the course of the sessions. In the European Union, Directive 2006/25/EC lays down minimum requirements for the protection of workers from risks arising from exposure to artificial optical radiation during their work (Article 1). It requires the employer to assess and, if necessary, measure or calculate the levels of optical radiation to which workers are likely to be exposed (Article 4). It applies through the national laws that transpose it (Article 14): have your employer obligations checked for your country.
Regulatory framework: Annex XVI of Regulation (EU) 2017/745
This is the most important point of this article.
What the text says
Regulation (EU) 2017/745 governs medical devices. By its Article 1(2), it also applies to groups of products that have no medical purpose, listed in its Annex XVI. Point 5 of that annex covers equipment emitting high intensity electromagnetic radiation (for example infra-red, visible light and ultra-violet) intended for use on the human body, including coherent and non-coherent sources, monochromatic and broad spectrum, such as lasers and intense pulsed light equipment, for skin resurfacing, tattoo or hair removal or other skin treatment.
The common specifications for these groups of products were adopted by Implementing Regulation (EU) 2022/2346, applicable from 22 June 2023 (its Article 2 provides for transitional provisions). Its Annex VI deals with this group of products and adds three clarifications:
- the term "skin resurfacing" includes "skin rejuvenation";
- "other skin treatment" includes in particular the non-medical treatment of pigmented skin areas and of scars that are not wounds within the meaning of Regulation 2017/745;
- the annex does not apply to equipment using infrared optical radiation to deliver heat to the body or to parts of the body, nor to sunbeds.
This exclusion concerns a use, the delivery of heat. It does not take a device out of scope merely because it emits infrared, and an LED bed also emits visible red: its qualification is a matter for the consultant's analysis.
Why the purpose matters
The same regulation defines the "intended purpose" of a product as the use for which it is intended according to the data supplied by the manufacturer on the label, in the instructions for use or in promotional or sales materials or statements. In other words, the qualification of a device does not depend only on its technology: it also depends on what is written on the label, in the manual, on the brochure and on the website.
Two shifts are possible:
- Towards the medical device. A device intended by the manufacturer, in particular, for the diagnosis, prevention, treatment or alleviation of a disease, or for the treatment or alleviation of an injury, falls within the definition of a medical device in Article 2 of the regulation.
- Towards Annex XVI. Without a medical purpose, equipment emitting high intensity radiation and intended for use on the human body may fall under point 5. After "such as", the text cites skin uses: presenting a device for use on the skin brings it closer to those examples.
In both cases, the manufacturer's obligations change in nature, and so does the timeline of a project.
What we do not decide
We do not say that an LED bed falls under Annex XVI. Nor do we say that it does not. The answer depends on the model, its intensity, its purpose as stated by the manufacturer and the way it is presented. The notion of "high intensity" itself calls for a specialist reading. No blog article, ours included, replaces that analysis.
Our position is constant: the qualification of each model is validated by a regulatory consultant before its page goes online and before your order. If a supplier tells you in one sentence that "it is not a medical device", ask which written analysis they rely on. The detailed reasoning is in light-based devices and regulation coming soon.
The other texts to know
Independently of this question, an LED bed is an item of electrical equipment. The texts that apply to this family are presented on our compliance page: Low Voltage Directive 2014/35/EU, Electromagnetic Compatibility Directive 2014/30/EU, RoHS 2011/65/EU, Radio Equipment Directive 2014/53/EU if the device includes Wi-Fi or Bluetooth, Regulation (EU) 2023/988 (General Product Safety Regulation), REACH and the professional WEEE scheme.
Our commitment fits in one sentence: we check and complete the compliance documentation of every piece of equipment before shipment. We never state that a specific model complies with a text before we have its file in hand.
The white label case
If the bed carries your brand, the question arises of who the manufacturer is within the meaning of Union law. That role carries obligations of its own; it is being validated by a regulatory consultant. The possible options (shell in your RAL colour, logo on the canopy and the screen where the factory allows it, programme names depending on the firmware) are described on the white label page.
What you can say, and what you cannot promise
Communication is part of compliance: as we have just seen, promotional and sales materials fall within the definition of a product's purpose. One word too many on a shop window can change the qualification of the device behind it.
The vocabulary we use
| To use | To avoid |
|---|---|
| Wellbeing, comfort, relaxation, recovery time, experience | Any result on the skin, pain, muscle recovery, sleep, weight, performance |
| Red and near-infrared light session | Medical vocabulary: care for a condition, patient, treatment protocol, prescription |
| Technical description: wavelengths, measured irradiance, session duration | Number of sessions "for a result" |
| Professional use, wellbeing equipment | "Proven", "validated by science", "recommended by doctors" |
| Goggles supplied, instructions displayed | "Completely safe", "no contraindication" |
This discipline applies to all your materials: website, social networks, service menu, what the team says in the booth, replies to reviews. It also applies to the programme names shown on the device screen. The full method is in communicating without claims coming soon, and the beauty salons page describes the framework for a beauty centre.
Price of a professional LED bed: what it is made of
We do not publish a range until it has been validated on real models. What we do give you is every item that makes up the budget, so that you can read a quote line by line and compare two offers on the same basis.
The price of the device
- Whole-body bed: on request
- Wall or floor-standing panel: on request
- Standing booth: on request
Indicative budget excluding transport, installation and local taxes. Quote tailored to your project.
What makes the price vary from one bed to another:
- The installed power and the measured irradiance, which also determine the power supply needed;
- The number of wavelengths emitted;
- The construction: structure, canopy, mattress, ventilation;
- The electronics: screen and programmes, depending on the firmware;
- The customisation: shell colour, logo, programme names;
- The documentation: a model delivered with usable irradiance measurements and a photobiological safety report does not cost the same as a model for which everything remains to be established.
What comes on top of the price of the device
| Item | What it covers | Amount |
|---|---|---|
| Transport and customs | Freight, import duties and taxes, delivery to site | By quote |
| Installation | Setting up, commissioning, team training (included in the Project and Turnkey levels) | By quote |
| Electrical work in the premises | Dedicated line, possible switch to 400 V | Quote from your electrician |
| Ventilation or air conditioning | Sized to the installed power | Quote from your installer |
| Additional tests | Third-party laboratory tests if the factory file is incomplete | Shown on the quote |
| Regulatory validation | Analysis of the model by a consultant | Specified before the order |
| Customisation | Shell, logo, programmes | By quote |
| Parts and maintenance | Spare LED modules, fans | By quote |
The commercial terms are not published either until they have been settled: on request.
Why the cheapest can cost more
A bed offered well below the other offers calls for three checks. Is the irradiance measured, or only stated? Does the photobiological safety report cover this model? Has the regulatory qualification been analysed in writing? A device without these three answers is not a bargain: it is a risk for you on the day of an inspection or an incident.
Documents to require before signing
Here are the documents to gather for LED equipment. You can use this list as it stands with any supplier.
- The signed EU declaration of conformity (low voltage, EMC, RoHS), with the texts and standards cited.
- The photobiological safety report for the model, with its classification.
- The irradiance measurements at a known distance, for each wavelength.
- The manual in French, with the eye protection instructions and the exposure times.
- The labelling: wavelengths, power, risk group.
- The technical file, or a statement that it is available.
- The written analysis of the regulatory qualification of the model with regard to Regulation (EU) 2017/745.
On each document, check four things: the exact model reference, the date, the identity of the signatory or the laboratory, and the consistency of the figures from one document to the next. A different irradiance between the sales sheet and the measurement report is information in itself.
For a bed under your brand, add the rating plate and the planned labelling, to be validated before manufacture.
Moving on to the quote request
A useful quote needs some information from you. Prepare it before writing to us:
- the format you have in mind (bed, panel, standing booth) and the number of devices;
- the floor area and height of the room, with a plan if you have one;
- the voltage available in the premises (230 V only or 400 V) and the subscribed power;
- the existing ventilation or air conditioning;
- the country of installation: France, Luxembourg, Belgium or Switzerland;
- your customisation needs (colour, logo, programmes);
- how you intend to present the service to your clients: this is what guides the regulatory validation.
From these elements, we tell you which models the factory can supply irradiance measurements and a photobiological safety report for, the points to be validated by the consultant, and the items of the budget. You can request your quote or book an appointment to talk it through.
Three points to remember before comparing offers:
- An LED bed is judged on measurements: irradiance at 10 cm for each wavelength, total electrical power, photobiological classification.
- The premises decide as much as the device: voltage, dedicated line, removal of heat.
- The regulatory qualification is validated before the order, and your communication is part of it.